High Frequency Power Line Noise Analysis Option for PS4500 & PS4000

Model No: FAO
$ 1345.00


AC Power line disturbances consist of these types in order of importance as an approximate %:

  • RMS sags (dips) and swells (80%)
  • Harmonics (harmonic distortion) (10%)
  • Transients (impulses) (10%)
  • High-Frequency Noise (<1%)

The PowerSight High Frequency Analysis Option (FAO) works with the PS4500 and PS4000 power quality analyzers and the HA1000 current probes. It is a combination of hardware, firmware, and software that allows you to analyze the presence of high-frequency power line noise content from 3,000 Hz to 100,000 Hz, and < 1 volt peak. The FAO option extends the capability of the PS4000 or PS4500 PowerSight power quality analyzer meter into a hand-held spectrum analyzer. This option is useful in determining whether power-line noise is present that may cause disruption of those equipment that are especially sensitive to such high-frequency noise.

The FAO is designed to measure continuous high-frequency noise. This is distinct from transient events that can be captured by the PS4500 Power Quality Analyzer impulse measurement system. The PS4500 captures transients as fast as 8us and up to 1000 volts peak. Example: Impulsive Transient

The PS4500/PS4000 measures harmonic content to the 63rd harmonic, or 3.8kHz. Harmonic Spectrum Example High-frequency noise however describes frequencies above this range of power harmonics – in the tens of kHz and higher. High-frequency noise is generated by certain types of loads (sources) that is subsequently conducted along power conductors and circuits. It is usually of very low voltage levels (note that high frequencies become attenuated rapidly over long distances) but the potential exists in rare situations for HF noise to affect sensitive devices. Most electronic devices have EMI/RF filtering at the front end of their power supplies that prevents ingress of conducted HF noise. However in rare situations where such filtering is not present, or if the noise couples into electronics via another route, then those equipment that are susceptible could be adversely affected causing disruption and mis-operation.

Continuous high-frequency noise generation usually comes from electronic sources such as lighting systems, adjustable speed drives, and UPS systems. Other devices that perform rectification of AC into DC also have the potential to generate high-frequency noise continuously. Non-electronic sources are poor wiring, or poor connections, bad contact problems. For example, intermittent connections, or loose fuse or breaker connections at panels can generate continuous high-frequency noise from arcing- or corona-type emission as infrastructure ages and devices and wiring degrade. Switch contacts that have deteriorated with age often have imperfect mating of contact surfaces (due to pitting) that will arc and spark as contacts come together during switching cycles. The contacts bounce and chatter generating impulsive noise but this is a transient phenomena that occurs only during a brief switching event. (Impulsive phenomena are best measured with the PS4500/PS4000 transient measuring system.) Transient events are distinct from a continuous source of high frequency noise such as on-going arcing or corona discharge phenomena.

We have supplied the FAO option in applications where high-frequency noise can affect sensitive electronics, or affect precise measurements, or interfere with specialized manufacturing processes, or communication signals. This includes sensitive bio-medical measurement equipment, military communication applications, and industrial control in manufacturing plants that have high populations of adjustable speed drives. (High levels of high-frequency noise can occur inside a manufacturing plant as a result of the aggregation of the noise from many individual drives. Our partner Environmental Potentials has more information on this type of application here: Variable Frequency Drives Application Note:)

Utility power supply is generally is not a major source of high-frequency noise.
It would be a rare situation if a power utility was a source of high-frequency noise. Plus, the source of noise would have to be close by and be continuous. The long line lengths of power distribution cables would rapidly attenuate any high frequencies. Any HF noise occurring on utility distribution systems (such as corona-type discharge or similar arcing) that would then find its way into low voltage circuits with any appreciable amplitude via conduction is very unlikely. HF noise generation, should it occur, is internal to a facility or operation.

For specialized applications where continuous high-frequency noise needs to be evaluated, use the FAO option — along with a PS4500 Power Quality Analyzer and specifically with the HA1000 Current Probes: only.

With the FAO option the high-frequency content of both voltage and current can be evaluated simultaneously. To analyze the high-frequency content of power circuits you will need to plug voltage leads into the FAO voltage conditioning accessory and connect the FAO to a PS4500/PS4000. To analyze the high-frequency content of current, connect an HA1000 current probe into a special adapter cable that then plugs into your PowerSight PS4500/PS4000 meter.

Features

Specifications

Only compatible with PS4000/PS4500 meters and the HA1000 current probes.

The FAO measures high-frequency power line noise frequencies with amplitudes from 100 µVrms to 1 Vrms and currents from 6 mA to 60 Arms (with an HA1000 current probe) in the range 3kHz to 100kHz.

More Images

Specials

Rent or Buy a PowerSight Power Analyzer from Summit Technology. Complete kits include probes and software. Single or Multi-unit. Fast Delivery.
Rent a PowerSight!
Need to solve an immediate problem? Contact us and we'll recommend a system complete with probes and our popular Report Writer software. Call 925-944-1212 for low rates!
SafeConnect
Safety first!
The SafeConnect accessory simplifies connecting to monitoring test points and keeps you safe from high voltages!
eFX6000: Wide Range Flexible Current Probe 1 - 6000 amps
Wide Range Flexible Current Probe
Having difficulty wiggling current probes into tight and confined spaces? You need our new 1 - 6000A flexible Rogowski-type probe.
PowerSight Power Analysis Software (+ Report Writer)
Put persuasion on paper!
Summarize, tabulate, and document your power study results automatically with our Report Writer. The Report Writer software comes with every PowerSight.
Jumbo Voltage Alligator Clips (set of 4)
Get a Good Grip with our New Jumbo Clip!
To make safe and secure voltage connections you need an alligator clip that just won’t let go! Our new “Jumbo” alligator clip has an excellent grasp of the situation.
Power Monitoring is a Process
Successful Power Studies Follow a Process. Read this paper to find out how to get successful power studies, first time, every time.

Talk to a Power Monitoring Expert.
Whatever your power study application we can help. Call 925-944-1212
NFPA 70E Electrical Testing Safety Application Note
Complying with NFPA 70E? Read this application note on safety.
Now you can get relief from wearing claustrophobic PPE. This paper describes how CAT IV and Bluetooth make the new PowerSight meters the safest to use.
Temperature Humidity Logger
Summit Technology introduces Temperature and Humidity measurement.
The TH-USB Temperature and Humidity logger at just $ 85 is a hot deal!